XRP-160/4500/2

Product Specifications

GENERATOR XRP-160/4500/2
   Voltage range 7.5 - 160 kV
  Adjustment increments (minimum step) 0.1 kV/step
  Accuracy ± 1% of output value ± 0.1 kV
  Reproducibility (at constant temperature) ± 0.01% of maximum kV-value
  High voltage ripple
(with 10 m high voltage cable)

5 V/mA, min. 20 V
  Temperature induced drift 80 ppm/°C based on output value
  Current range 0 - 45 mA
  Adjustment standard range in 0.05 mA steps from 0.5 mA to max. value
  High resolution range (recommended) in 0.01 mA steps from 0.0 mA to max. value
  Accuracy (at constant temperature) ± 0.2% of output value ± 0.01 mA
  Reproducibility (at constant temperature) ± 2 µA
 
Temperature induced drift
50 ppm/°C of output value
(on request 30 ppm/°C possible)
  Maximum power 4500 W
  High voltage connector type R24
     
CONTROL UNIT XRG XRG
  Dimensions (W x H x D) 483 mm x 133 mm x 300 mm
  Weight 12.5 kg
     
POWER SUPPLY - XRP POWER XRP-POWER-4500
  Dimensions (W x H x D) 340 mm x 350 mm x 625 mm
  Weight 45 kg
     
HIGH VOLTAGE TANK (OIL INSULATED) XRP-T160K
  Dimensions (W x H x D) 375 mm x 335 mm x 625 mm
  Weight 80 kg
     
SAFETY FEATURES  
  Two separate, independently monitored safety circuits (fail-safe, 24 V)
  Continuous system-function monitoring with fully automated system shut-down and failure indication
  Automated filament post-heating high voltage capacitor discharge upon termination
  “X-ray on” warning lamp monitoring provided (fail-safe)
  External safety circuit for automated systems (24 V)
  High voltage primary circuit interruption for CDRH switch (US standard)
  Monitored door lock feature
  External coolant monitoring